diff --git a/Logic2_to_FPGA.qsf b/Logic2_to_FPGA.qsf
index c2f067d..064233e 100644
--- a/Logic2_to_FPGA.qsf
+++ b/Logic2_to_FPGA.qsf
@@ -52,7 +52,7 @@ set_global_assignment -name EDA_TIME_SCALE "1 ps" -section_id eda_simulation
set_global_assignment -name EDA_OUTPUT_DATA_FORMAT "VERILOG HDL" -section_id eda_simulation
set_global_assignment -name POWER_PRESET_COOLING_SOLUTION "23 MM HEAT SINK WITH 200 LFPM AIRFLOW"
set_global_assignment -name POWER_BOARD_THERMAL_MODEL "NONE (CONSERVATIVE)"
-set_global_assignment -name PARTITION_NETLIST_TYPE POST_FIT -section_id Top
+set_global_assignment -name PARTITION_NETLIST_TYPE SOURCE -section_id Top
set_global_assignment -name PARTITION_FITTER_PRESERVATION_LEVEL PLACEMENT_AND_ROUTING -section_id Top
set_global_assignment -name PARTITION_COLOR 16764057 -section_id Top
set_global_assignment -name STRATIX_DEVICE_IO_STANDARD "2.5 V"
@@ -71,38 +71,37 @@ set_global_assignment -name VERILOG_FILE pattern_player.v
set_instance_assignment -name SLEW_RATE 2 -to GPIO0
set_global_assignment -name ENABLE_SIGNALTAP ON
set_global_assignment -name USE_SIGNALTAP_FILE stp2.stp
-set_global_assignment -name SIGNALTAP_FILE stp.stp
set_global_assignment -name SLD_NODE_CREATOR_ID 110 -section_id auto_signaltap_0
set_global_assignment -name SLD_NODE_ENTITY_NAME sld_signaltap -section_id auto_signaltap_0
set_instance_assignment -name POST_FIT_CONNECT_TO_SLD_NODE_ENTITY_PORT acq_clk -to CLK50 -section_id auto_signaltap_0
set_global_assignment -name SLD_NODE_PARAMETER_ASSIGNMENT "SLD_RAM_BLOCK_TYPE=AUTO" -section_id auto_signaltap_0
-set_global_assignment -name SLD_NODE_PARAMETER_ASSIGNMENT "SLD_DATA_BITS=1" -section_id auto_signaltap_0
-set_global_assignment -name SLD_NODE_PARAMETER_ASSIGNMENT "SLD_TRIGGER_BITS=1" -section_id auto_signaltap_0
set_global_assignment -name SLD_NODE_PARAMETER_ASSIGNMENT "SLD_NODE_INFO=805334528" -section_id auto_signaltap_0
set_global_assignment -name SLD_NODE_PARAMETER_ASSIGNMENT "SLD_POWER_UP_TRIGGER=0" -section_id auto_signaltap_0
-set_global_assignment -name SLD_NODE_PARAMETER_ASSIGNMENT "SLD_SEGMENT_SIZE=128" -section_id auto_signaltap_0
set_global_assignment -name SLD_NODE_PARAMETER_ASSIGNMENT "SLD_ATTRIBUTE_MEM_MODE=OFF" -section_id auto_signaltap_0
set_global_assignment -name SLD_NODE_PARAMETER_ASSIGNMENT "SLD_STATE_FLOW_USE_GENERATED=0" -section_id auto_signaltap_0
set_global_assignment -name SLD_NODE_PARAMETER_ASSIGNMENT "SLD_STATE_BITS=11" -section_id auto_signaltap_0
set_global_assignment -name SLD_NODE_PARAMETER_ASSIGNMENT "SLD_BUFFER_FULL_STOP=1" -section_id auto_signaltap_0
set_global_assignment -name SLD_NODE_PARAMETER_ASSIGNMENT "SLD_CURRENT_RESOURCE_WIDTH=1" -section_id auto_signaltap_0
set_global_assignment -name SLD_NODE_PARAMETER_ASSIGNMENT "SLD_TRIGGER_LEVEL=1" -section_id auto_signaltap_0
-set_global_assignment -name SLD_NODE_PARAMETER_ASSIGNMENT "SLD_SAMPLE_DEPTH=128" -section_id auto_signaltap_0
set_global_assignment -name SLD_NODE_PARAMETER_ASSIGNMENT "SLD_ADVANCED_TRIGGER_ENTITY=basic,1," -section_id auto_signaltap_0
set_global_assignment -name SLD_NODE_PARAMETER_ASSIGNMENT "SLD_TRIGGER_LEVEL_PIPELINE=1" -section_id auto_signaltap_0
set_global_assignment -name SLD_NODE_PARAMETER_ASSIGNMENT "SLD_ENABLE_ADVANCED_TRIGGER=0" -section_id auto_signaltap_0
-set_global_assignment -name SIGNALTAP_FILE stp1.stp
set_global_assignment -name SIGNALTAP_FILE stp2.stp
-set_global_assignment -name SLD_NODE_PARAMETER_ASSIGNMENT "SLD_INVERSION_MASK=000000000000000000000000" -section_id auto_signaltap_0
-set_global_assignment -name SLD_NODE_PARAMETER_ASSIGNMENT "SLD_INVERSION_MASK_LENGTH=24" -section_id auto_signaltap_0
set_global_assignment -name SLD_NODE_PARAMETER_ASSIGNMENT "SLD_STORAGE_QUALIFIER_INVERSION_MASK_LENGTH=0" -section_id auto_signaltap_0
set_location_assignment PIN_84 -to GPIO1
set_instance_assignment -name IO_STANDARD "3.3-V LVTTL" -to GPIO1
+set_instance_assignment -name POST_FIT_CONNECT_TO_SLD_NODE_ENTITY_PORT trigger_in -to clk50_div2 -section_id auto_signaltap_0
+set_global_assignment -name SLD_NODE_PARAMETER_ASSIGNMENT "SLD_TRIGGER_IN_ENABLED=1" -section_id auto_signaltap_0
+set_instance_assignment -name SLEW_RATE 2 -to GPIO1
+set_global_assignment -name SLD_NODE_PARAMETER_ASSIGNMENT "SLD_SEGMENT_SIZE=131072" -section_id auto_signaltap_0
+set_global_assignment -name SLD_NODE_PARAMETER_ASSIGNMENT "SLD_SAMPLE_DEPTH=131072" -section_id auto_signaltap_0
set_instance_assignment -name POST_FIT_CONNECT_TO_SLD_NODE_ENTITY_PORT acq_trigger_in[0] -to clk50_div2 -section_id auto_signaltap_0
set_instance_assignment -name POST_FIT_CONNECT_TO_SLD_NODE_ENTITY_PORT acq_data_in[0] -to clk50_div2 -section_id auto_signaltap_0
-set_instance_assignment -name POST_FIT_CONNECT_TO_SLD_NODE_ENTITY_PORT trigger_in -to clk50_div2 -section_id auto_signaltap_0
+set_global_assignment -name SLD_NODE_PARAMETER_ASSIGNMENT "SLD_DATA_BITS=1" -section_id auto_signaltap_0
+set_global_assignment -name SLD_NODE_PARAMETER_ASSIGNMENT "SLD_TRIGGER_BITS=1" -section_id auto_signaltap_0
+set_global_assignment -name SLD_NODE_PARAMETER_ASSIGNMENT "SLD_INVERSION_MASK=0000000000000000000000000000000000" -section_id auto_signaltap_0
+set_global_assignment -name SLD_NODE_PARAMETER_ASSIGNMENT "SLD_INVERSION_MASK_LENGTH=34" -section_id auto_signaltap_0
set_global_assignment -name SLD_NODE_PARAMETER_ASSIGNMENT "SLD_NODE_CRC_LOWORD=44983" -section_id auto_signaltap_0
-set_global_assignment -name SLD_NODE_PARAMETER_ASSIGNMENT "SLD_NODE_CRC_HIWORD=12698" -section_id auto_signaltap_0
-set_global_assignment -name SLD_NODE_PARAMETER_ASSIGNMENT "SLD_TRIGGER_IN_ENABLED=1" -section_id auto_signaltap_0
+set_global_assignment -name SLD_NODE_PARAMETER_ASSIGNMENT "SLD_NODE_CRC_HIWORD=43530" -section_id auto_signaltap_0
set_global_assignment -name SLD_FILE db/stp2_auto_stripped.stp
set_instance_assignment -name PARTITION_HIERARCHY root_partition -to | -section_id Top
\ No newline at end of file
diff --git a/error.txt b/error.txt
new file mode 100644
index 0000000..d9e90d9
--- /dev/null
+++ b/error.txt
@@ -0,0 +1,25 @@
+Error (265013): Can't open SignalTap II Logic Analyzer. Verify that the license file exists and is stored in the correct location. If you are using the Quartus II Web Edition software, you must turn on the TalkBack feature to use the SignalTap II Logic Analyzer.
+Выполнено 2 шага
+Сообщение говорит, что Quartus не даёт запустить SignalTap, потому что для твоей редакции нужна включённая «телеметрия» (TalkBack) и корректная лицензия.
+
+Если у тебя Quartus II Web Edition или Quartus Prime Lite
+Для Web / Lite SignalTap работает только при включённом TalkBack:
+
+Включить TalkBack:
+
+Меню Tools → Options.
+
+В дереве слева выбрать Internet Connectivity.
+
+Нажать кнопку TalkBack Options….
+
+Поставить галку «Turn on the Quartus II software TalkBack feature» или «Enable sending TalkBack data to Altera / Intel».
+
+Нажать OK, потом ещё раз OK, чтобы выйти из Options.
+
+Перезапустить Quartus и проект, затем:
+
+Снова попробовать открыть Tools → SignalTap II Logic Analyzer.
+
+При необходимости пересобрать проект, потому что при отключённом TalkBack SignalTap не встраивался.
+
diff --git a/stp2.stp b/stp2.stp
index 6d4db68..330510e 100644
--- a/stp2.stp
+++ b/stp2.stp
@@ -4,25 +4,20 @@
-
-
-
-
-
-
-
-
-
-
-
-
+
+
+
+
+
+
+
-
+
-
+
@@ -37,18 +32,18 @@
-
+
-
+
-
+
-
+
@@ -78,10 +73,21 @@
-
+
+
+
+
+
+
+
+
+
+
+
+